Envelopes

Plant specification

Newell WTP

Newell Regional Services Corp. (NRSC) · Brooks, AB, Canada

Status not reported
Pall/Aria Microza microfiltration (MF)
Source: Lake Newell Reservoir
OEM: Pall (now AriaFiltra)
OEM: Kinetico
Three envelopes — do not conflate them
32 and 40 MLD are theoretical membrane-system capacities derived from Pall's later 8-MLD/rack design basis, not demonstrated plant capacity. April 2026 data shows racks operating materially below that flux. Confirm common-system ratings (feed pumps, feed strainers, RF pumps/tank, compressed air, CIP, clearwell hydraulics, discharge piping) before using 32/40 MLD in any capacity, hydraulic guarantee, or expansion study.
Envelope 1

Physical

Racks
4
Modules
400
Membrane area
~20,000 m²
Envelope 2

Pall design (theoretical)

Per rack
8 MLD
Flux
78–81 LMH
Recovery
95.8–96 %
4 racks / 5-rack expansion
32 / 40 MLD
Depends on feed-water quality, feed pumps, feed strainers, compressed-air capacity, RF/backwash equipment, piping hydraulics, and other ancillary equipment; Pall did not supply or re-rate several of these systems in the 2017 expansion review
Envelope 3

Observed operating (Apr 2026)

Per rack
4.3 MLD typical, 5.9 MLD high
Flux
36 LMH typical (30–45)
TMP
~100 kPa
Share of Pall design flux
45-55%

Pall design vs observed operation

Rack 1, April 2026, against Pall's design basis

Output per rack (MLD)

Pall design

8

Observed, high

5.9

Observed, typical

4.3

Flux (LMH)

Pall design

78–81

Observed

30–45 · typ. 36

Pressure envelope

Pressure (kPa)

Module O&M normal range

0–345 (0–50 psig)

Upper-normal TMP band

130–145

Feed pressure, observed

113–166 · typ. 135

TMP, observed

76–129 · typ. 98

Observed operation is within the general O&M pressure range, but 50 psi is a broad module limit, not an operational TMP target. Alarm/shutdown setpoints should come from the plant PLC/SFD/O&M settings.

Temperature envelope

Temperature (°C)

Membrane design range

0–40

CIP circuit, max observed

38 max

CIP pump discharge (full speed)
240 kPa
CIP est. suction (max)
30 kPa
~38C CIP condition is near the upper end of the 0-40C membrane range; cleaning is governed by its own recipe/chemistry limits