DEMODemonstration build · sample data is marked · not connected to live plant systems

Water Quality

Plant specification

Newell WTP

Newell Regional Services Corp. (NRSC) · Brooks, AB, Canada

Status not reported
Pall/Aria Microza microfiltration (MF)
Source: Lake Newell Reservoir
OEM: Pall (now AriaFiltra)
OEM: Kinetico

Source water — Lake Newell Reservoir

2022 Pall design basis vs 2007 pilot measurements (August-October 2007)

Parameter2022 design basis2007 pilot, phase 12007 pilot, phase 2UnitComparison
Turbidity5–501.812.51NTU
Pilot below design range
Total suspended solids10–100——mg/L—
Iron≤ 2——mg/L—
Manganese≤ 1——mg/L—
Total organic carbon3–62.93.3mg/L
Pilot straddles lower limit
Dissolved organic carbon—2.83mg/L—
Hardness (as CaCO₃)50–350——mg/L—
Alkalinity (as CaCO₃)60–320111116mg/L
Pilot within design range
pH—8.28.4——
UV254—0.050.05cm⁻¹—
Colour—2129ACU—
Total dissolved solids—171.5174.2mg/L—
Aluminum—0.010.02mg/L—
Design basis values are assumed
Assumed values based on similar source waters; subject to change after review of actual source data - not measured extremes
Pilot data is historic
Far lower turbidity than the 5-50 NTU design envelope assumed in 2022; historic dataset, not necessarily representative of current worst-case source water

Treated water objectives

2022 Pall design, membrane filtrate

Filtrate turbidity, 95% of time
≤ 0.1 NTU
Filtrate turbidity, always
≤ 0.2 NTU
SDI, 95% of time
≤ 2.5
Pilot filtrate achieved
0.01 NTU
Membrane-system objectives only, not a complete potable-water compliance specification